Beaver-Visitec International, Inc
24 recall(s) on record — most severe on record: Class II.
Activity by year
- Recalls (24)
- Inspections (1)
Devices registered here (2)
- Laser, OphthalmicProduct code HQF (opens in a new tab) · Class II · Ophthalmic · 21 CFR 886.4390
- Endoscope, OphthalmicProduct code KYH (opens in a new tab) · Class II · Gastroenterology, Urology · 21 CFR 876.1500
Recalls & enforcement
20251 record
- Class IIOngoing2025-12-05Manufacturing deviation in which the ferrites specified for the USB cable assembly linking the Nurse Monitor touchscreen to the System Controller were not installed as intended. The omission of the ferrites on the USB communication cable results in non-conformance to the design s…
20243 records
- Class IIOngoing2024-07-26Due to a voluntary recall of low dead space syringes, and luer slip tip syringes manufactured by Sol-Millennium Medical (Sol-M), Inc. These syringes manufactured by Sol-M are present in some of BVI CustomEyes Procedure Packs.
- Class IIOngoing2024-05-10The wrong configuration of the blade was in the package. The bevel was on the opposite side, instead of being in front (bevel up) it was in the back (bevel down).
- Class IIOngoing2024-02-02Pack and pouch label is missing the manufacturing and expiration date.
20233 records
- Class IIOngoing2023-10-10One lot of Part Number 373025, Xstar® Kojo Safety Slit Knife 2.5mm 45® bevel up, incorrectly contains a bevel down blade instead of a bevel up blade.
- Class IIOngoing2023-08-25One lot of Conventional Crescent Knife 2.5mm, 55 degrees bevel-up contains a bevel down blade.
- Class IIOngoing2023-03-17Device suddenly and forcefully disassembled after cryotherapy, potential for long-term or permanent impairment of a patient or user if a CryoTreq device suddenly or forcefully disassembles during a cryosurgery procedure.
20224 records
- Class IIOngoing2022-12-20Device packaging may contain open seals, compromising product sterility.
- Class IIOngoing2022-11-30Packaging sterile barrier has been compromised. Open seals can lead to a loss of device sterility and may lead to infection
- Class IIOngoing2022-09-30Incorrect configuration of the blades in the package. The blades curve to the right instead of curving to the left. If used may cause cause unintended tissue damage during the procedure or if noticed prior to use may cause a delay in surgery
- Class IIOngoing2022-04-26Boxes labeled as Wet-Field Eraser, 18GA Blunt Tip, 45Deg., were shipped containing incorrect product a Wet-Field Eraser, 18GA Bevel Tip, Straight, Part Number: 221250
20212 records
- Class IIOngoing2021-11-17Kit packaging may have small holes compromising product sterility
- Class IIOngoing2021-10-08Product packaged as Beaver Xstar Crescent Knife, 2.5mm, 55 degrees bevel-down blades contain bevel-up blades
20192 records
- Class IITerminated2019-03-12Mislabeled. The package labeling indicates a size 2.4mm, 45 degree Double Bevel knife however, the marking on device shows a 2.75mm size device
- Class IIITerminated2019-02-19The product contains a misprinted expiration date on the peel pack. Both were printed as "180615", which is the lot number. The Lot number is correct.
20186 records
- Class IITerminated2018-11-30Certain lots are missing a protective sheath component over the silicone tip, which may result in the silicone tip breaking or detaching at the metal tube component. If the tip becomes detached during a procedure while in the eye, the fragment will need to be retrieved to mitigat…
- Class IITerminated2018-07-19A small number of devices in this lot may have a melted cap and a hole formed through the packaging. The risk is potentially the product will no longer be sterile for use and may cause harm to a patient.
- Class IITerminated2018-06-18Mislabel of product 373726 Lot 6001700 with 374891 Lot 6001701 on individual packages within the correctly labeled shelf carton.
- Class IITerminated2018-05-14Blades are loose in handles and may fall out due to non cured epoxy
- Class IITerminated2018-02-26Incorrect tip was used during manufacturing of the Osher Thermodot Marker. The markers have a needle tip instead of the proper flat tip.
- Class IITerminated2018-02-26Products were packaged with incorrect labeling,
20171 record
- Class IITerminated2017-11-03The protective shield was retracted, and the blade was exposed.
20151 record
- Class IITerminated2015-05-01Devon Light Glove in procedure kits may have holes/slits compromising sterility of the product
20141 record
- Class IITerminated2014-05-06Contains a sharp tip needle when the product should contain a blunt tip cannula
FDA inspections (1)
- NAI2020-03-05No Action Indicated · Compliance: Devices; Postmarket Assurance: Devices; Radiation Control and Health Safety Act
Source: U.S. FDA Inspections Dashboard (opens in a new tab) (device inspection classifications, 2016–present). Data as of 2026-10-06. The dashboard profile can take several seconds to load.
Related
Source: U.S. FDA via openFDA (opens in a new tab) (device registration & enforcement). Data as of 2026-10-06. Verify this facility record at FDA → (opens in a new tab)
Cite this record
RegWarden. “Beaver-Visitec International, Inc (FEI 1000122089) — FDA facility record.” Compiled from U.S. FDA public records (openFDA; FDA Data Dashboard). Data as of 2026-10-06. https://regwarden.com/facility/1000122089-beaver-visitec-international-inc/
Alerts for Beaver-Visitec International, Inc
Watchlist alerts will email you when FDA publishes a new recall, inspection classification, or warning letter for a facility you follow. They aren't open to the public yet — leave your email and we'll tell you when they are.
Want a one-page facility brief?
A single-page summary of this facility's registration and recall history for diligence. Not selling it yet — register interest and we'll follow up.