RegWardenFDA facility compliance records
Recall

Class II — Isopure Corp

Recalling firmISOPURE CORP.
Registered facilityISOPURE, CORP. (the firm's only registered facility)
ClassificationClass II
StatusTerminated
ReasonThere is a potential for an uneven plastic encapsulation of the magnet ring during the molding process and partial axial displacement. This issue could cause uneven wear during use, cause exposure of the magnet to solution, and thereby result in corrosion and the presence of iron.
ProductFinish Thompson Centrifugal Pump Model #110192-3 (sold as spare part)
Quantity8
DistributionThe products were distributed to the following US states: AL, FL, GA, MA, MD, MN, NC, NM, NY, OH, OK, TX, and VA.
Initiated2019-04-19
Classified2020-01-18
Terminated2020-05-29
Recall numberZ-0823-2020
InitiationVoluntary: Firm initiated

Source: U.S. FDA via openFDA (opens in a new tab) (device registration & enforcement). Data as of 2026-10-06. Verify this recall record at FDA → (opens in a new tab)

Cite this record

RegWarden. “Class II recall — Isopure Corp (Z-0823-2020).” Compiled from U.S. FDA public records (openFDA; FDA Data Dashboard). Data as of 2026-10-06. https://regwarden.com/recall/83990/