BARCO N.V.
7 recall(s) on record — most severe on record: Class II.
Activity by year
- Recalls (7)
- Inspections (3)
Devices registered here (1)
- Display, Cathode-Ray Tube, MedicalProduct code DXJ (opens in a new tab) · Class II · Cardiovascular · 21 CFR 870.2450
Recalls & enforcement
- Class IIOngoing2025-05-09Cathode ray tube display system encoders and decoders have same MAC address; new system setup with two or more affected units can lead to systems not functioning reliably:audio, video and/or control signals might be interrupted or fall away, displays might switch to failover and …
- Class IICompleted2024-04-24We have identified a potential issue with the SFP+ module supplied by Molex (Part Number: B620050) when connected to the ETH0 slot of either the MNA-6x0 ENC HDMI or MNA-4x0 ENC HDMI. In some instances, this connection may render the first HDMI channel inaccessible, making both th…
- Class IIOngoing2023-12-20Barco became aware of a problem with I2C cables in the manufacturing process of a limited batch of MDSC-85xx NXF products. The functionality of the built-in MNA decoder is blocked.
- Class IIOngoing2022-07-27installation issues
- Class IITerminated2021-01-22A number of MDNC-3421 displays were shipped while not being DICOM-compliant. These displays will not pass DICOM acceptance tests.
- Class IITerminated2017-03-30If metal strips are removed and re-applied to another display, there is potential for the metal strips to be deformed resulting in a smaller contact surface with the front cover magnet strips. There is a risk that the protective front cover could come loose and may fall down.
- Class IITerminated2015-05-28User settings were no longer on the monitor's memory after these systems were powered off and back on.
FDA inspections (3)
- NAI2026-06-05No Action Indicated · Compliance: Devices; Postmarket Assurance: Devices; Radiation Control and Health Safety Act · citations posted
- VAI2023-09-14Voluntary Action Indicated · Compliance: Devices; Postmarket Assurance: Devices · citations posted
- NAI2018-09-21No Action Indicated · Compliance: Devices; Postmarket Assurance: Devices
Source: U.S. FDA Inspections Dashboard (opens in a new tab) (device inspection classifications, 2016–present). Data as of 2026-10-06. The dashboard profile can take several seconds to load.
Related
- All facilities operated by BARCO NV
- Barco (Suzhou) Healthcare Technology Co., Ltd. (CN)
- Barco Inc Portland (OR)
- BARCO S.R.L. (IT)
- Barco, Inc (GA)
Source: U.S. FDA via openFDA (opens in a new tab) (device registration & enforcement). Data as of 2026-10-06. Verify this facility record at FDA → (opens in a new tab)
Cite this record
RegWarden. “BARCO N.V. (FEI 3004455125) — FDA facility record.” Compiled from U.S. FDA public records (openFDA; FDA Data Dashboard). Data as of 2026-10-06. https://regwarden.com/facility/3004455125-barco-n-v/
Alerts for BARCO N.V.
Watchlist alerts will email you when FDA publishes a new recall, inspection classification, or warning letter for a facility you follow. They aren't open to the public yet — leave your email and we'll tell you when they are.
Want a one-page facility brief?
A single-page summary of this facility's registration and recall history for diligence. Not selling it yet — register interest and we'll follow up.