NIHON KOHDEN TOMIOKA PRODUCTION CENTER
9 recall(s) on record — most severe on record: Class II.
Activity by year
- Recalls (9)
- Inspections (1)
Devices registered here (7)
- Device, Nerve Conduction Velocity MeasurementProduct code JXE (opens in a new tab) · Class II · Neurology · 21 CFR 882.1550
- Stimulator, Auditory, Evoked ResponseProduct code GWJ (opens in a new tab) · Class II · Neurology · 21 CFR 882.1900
- Device, Galvanic Skin Response MeasurementProduct code GZO (opens in a new tab) · Class II · Neurology · 21 CFR 882.1540
- Electromyograph, DiagnosticProduct code IKN (opens in a new tab) · Class II · Physical Medicine · 21 CFR 890.1375
- Stimulator, Electrical, Evoked ResponseProduct code GWF (opens in a new tab) · Class II · Neurology · 21 CFR 882.1870
- Full-Montage Standard ElectroencephalographProduct code GWQ (opens in a new tab) · Class II · Neurology · 21 CFR 882.1400
- Stimulator, Photic, Evoked ResponseProduct code GWE (opens in a new tab) · Class II · Neurology · 21 CFR 882.1890
Recalls & enforcement
- Class IIOngoing2024-09-18Due to oximeters not having FDA market approval or clearance to distribute in the U.S.
- Class IIOngoing2024-04-29Due to software issue the device may give false "SpO2 Probe Failure" alarm
- Class IIOngoing2022-04-29Due to products being shipped/distributed to customers after the products expiration date had past.
- Class IIOngoing2021-01-08Incorrect Date Stamp or No Data Transfer on Telemetry Receiver and Transmitter.
- Class IIOngoing2020-12-21Medical device non-conformance to electrical safety standard (IEC 60601-1).
- Class IITerminated2017-03-13The Pause function on central monitors will not automatically resume when connected to a Life Scope G9 patient monitor.
- Class IITerminated2015-04-14Nihon Kohden America (NKA) is recalling the Remote Network Station (RNS) 9703 because it may fail to sound.
- Class IITerminated2014-06-03Software Version 02-26, when used with the Central Nursing Station (CNS) 6201, (PU-621 RA) may unexpectedly and without warning reboot, resulting in a period of approximately 3 minutes during which time the system does not display patient data and does not emit alarms based on th…
- Class IITerminated2012-01-19The MEE-1000A Neuromaster had defective printed circuit boards (PCBs). Gas arrestors on these boards which were intended to provide protection from electrostatic discharge failed to prohibit unintentional current flow.
FDA inspections (1)
- NAI2016-03-25No Action Indicated · Compliance: Devices
Source: U.S. FDA Inspections Dashboard (opens in a new tab) (device inspection classifications, 2016–present). Data as of 2026-10-06. The dashboard profile can take several seconds to load.
Related
- All facilities operated by NIHON KOHDEN CORP.
- NIHON KOHDEN AMERICA, INC. (CA)
- Nihon Kohden Tomioka Corporation (JP)
- Nihon Kohden Corporation - Eastern Japan Logistics Center (JP)
- Nihon Kohden Corporation - Tokorozawa establishment Advanced Technology Center (JP)
- NIHON KOHDEN CORP. (JP)
- Nihon Kohden America Fulfillment Center (CA)
- Nihon Kohden Tomioka Corporation Nihon Kohden Kawamoto Production Center (JP)
- Nihon Vinyl Cord Corporation - Kodama Second Factory (JP)
- Nihon Kohden Digital Health Solutions, LLC. (CA)
- Nihon Vinyl Cord Corporation - Shimo-ongata Factory (JP)
Source: U.S. FDA via openFDA (opens in a new tab) (device registration & enforcement). Data as of 2026-10-06. Verify this facility record at FDA → (opens in a new tab)
Cite this record
RegWarden. “NIHON KOHDEN TOMIOKA PRODUCTION CENTER (FEI 3002807739) — FDA facility record.” Compiled from U.S. FDA public records (openFDA; FDA Data Dashboard). Data as of 2026-10-06. https://regwarden.com/facility/3002807739-nihon-kohden-tomioka-production-center/
Alerts for NIHON KOHDEN TOMIOKA PRODUCTION CENTER
Watchlist alerts will email you when FDA publishes a new recall, inspection classification, or warning letter for a facility you follow. They aren't open to the public yet — leave your email and we'll tell you when they are.
Want a one-page facility brief?
A single-page summary of this facility's registration and recall history for diligence. Not selling it yet — register interest and we'll follow up.