MICROAIRE SURGICAL INSTRUMENTS LLC
12 recall(s) on record — most severe on record: Class II.
Activity by year
- Recalls (12)
- Inspections (1)
Devices registered here (3)
- Knife, SurgicalProduct code EMF (opens in a new tab) · Class I · General, Plastic Surgery · 21 CFR 878.4800
- Sterilization Wrap Containers, Trays, Cassettes & Other AccessoriesProduct code KCT (opens in a new tab) · Class II · General Hospital · 21 CFR 880.6850
- ArthroscopeProduct code HRX (opens in a new tab) · Class II · Orthopedic · 21 CFR 888.1100
Recalls & enforcement
- Class IIOngoing2025-05-07Potential that the blade can unintentionally cut tissue prior to the user deploying the blade.
- Class IITerminated2019-06-26There was a higher than normal incidence rate of the blade not retracting when tightening.
- Class IITerminated2018-04-19The Instructions for Use (IFU) is incorrect with regards to sterilization parameters and must be replaced.
- Class IITerminated2017-05-22One lot was found to contain both the correct twist drill (1.6mm) as well as an incorrect twist drill (2.0mm)
- Class IITerminated2017-02-21Mislabeling on three lots of K-Wires. The incorrect product description " dual trocar" instead of "single trocar" was on the product label on the following parts: 1600-9355NS (lot 61005), 1600-9625NS (lot 60297), and 1604-162NS (lot 62856).
- Class IITerminated2016-05-06MicroAire has initiated a limited recall (29 Units)on the Endotine Transbleph 3.5 (CFD-080-0167), Lot # 285373, due to minor mislabeling ( the front label is correct, but the side label lists an incorrect part number, i.e. CFD-080-0177).
- Class IITerminated2016-03-11MicroAire discovered that 20 suspect Impactor instruments ( MicroAire Pneumatic Impactor) were shipped to end users and were missing the lock and unlock symbol markings on them.
- Class IITerminated2016-02-08MicroAire has initiated a recall on product PAL-R4011XL (40cm x 4mm Del Vecchio French Rasp cannula), due to our receipt of three (3) complaints that it bent or broke during surgery. Accordingly, the PAL-R4011XL has also been put on production hold until further notice.
- Class IITerminated2016-02-08Complaints that the cannula bent/broke during surgery.
- Class IITerminated2015-06-12There is potential risk of electrical shock if lead wires inside the device become detached and the ground connection fails.
- Class IITerminated2013-08-12A medical device used in surgical procedures was packaged in a pouch in which a defective seal may compromise sterility
- Class IITerminated2012-04-26Medical device was not manufactured under Good Manufacturing Procedures and a user may be unable to sterilize the device according to procedures.
FDA inspections (1)
- VAI2016-03-17Voluntary Action Indicated · Compliance: Devices; Postmarket Assurance: Devices · citations posted
Source: U.S. FDA Inspections Dashboard (opens in a new tab) (device inspection classifications, 2016–present). Data as of 2026-10-06. The dashboard profile can take several seconds to load.
Related
Source: U.S. FDA via openFDA (opens in a new tab) (device registration & enforcement). Data as of 2026-10-06. Verify this facility record at FDA → (opens in a new tab)
Cite this record
RegWarden. “MICROAIRE SURGICAL INSTRUMENTS LLC (FEI 2020601) — FDA facility record.” Compiled from U.S. FDA public records (openFDA; FDA Data Dashboard). Data as of 2026-10-06. https://regwarden.com/facility/2020601-microaire-surgical-instruments-llc/
Alerts for MICROAIRE SURGICAL INSTRUMENTS LLC
Watchlist alerts will email you when FDA publishes a new recall, inspection classification, or warning letter for a facility you follow. They aren't open to the public yet — leave your email and we'll tell you when they are.
Want a one-page facility brief?
A single-page summary of this facility's registration and recall history for diligence. Not selling it yet — register interest and we'll follow up.